PP-Mod tube
Characteristics
Body | Polyamide PA6 V2 |
O-ring | NBR (optional) |
Thread Type | Metric (EN 60423) |
Tightness | IP68 |
Continuous working temperature | -20 ºC +100 ºC |
Properties
Anti-vibration
Anti-pullHigh UV resistance
Easy assemblyVDE certified (40030037)
Free of halogens
Product description
An anti-twist cable gland is a special type of cable gland for applications where the cable connected to the cable gland is in continuous movement.
Thanks to its cap design, the anti-twist cable gland protects the initial section of the cable and provides security against movements and friction that may arise from the operation of the equipment.
Anti-twist cable glands are used in sectors such as robotics. The use and movement of electrical equipment constantly tests the cable, so it is essential to cover it and ensure its integrity.
Cable glands are used in any type of installation, machinery or equipment that requires a continuous electrical supply and is responsible for ensuring its connection.
Threads | Code | Hmm | GL mm | mm | mm |
M 12 X 1.5 | OMRB 17 | 57 | 8 | 15 | 3-6,5 |
M 16 X 1.5 | OMRB 18 | 70 | 8 | 19 | 4-8 |
M 16 X 1.5 | OMRB 19 | 81 | 10 | 22 | 5-10 |
M 20 X 1.5 | OMRB 20 | 89 | 10 | 24 | 6-12 |
M 20 X 1.5 | OMRB 21 | 107 | 10 | 27 | 10-14 |
M 25 X 1.5 | OMRB 22 | 124 | 10 | 33 | 13-18 |
LONG THREAD CABLE GLAND | |||||
M 12 X 1.5 | OMRB 17L | 57 | 15 | 15 | 3-6,5 |
M 16 X 1.5 | OMRB 18L | 70 | 15 | 19 | 4-8 |
M 16 X 1.5 | OMRB 19L | 81 | 15 | 22 | 5-10 |
M 20 X 1.5 | OMRB 20L | 89 | 15 | 24 | 6-12 |
M 20 X 1.5 | OMRB 21L | 107 | 15 | 27 | 10-14 |
M 25 X 1.5 | OMRB 22L | 124 | 15 | 33 | 13-18 |